    Powering a detached garage, a shop, a pool house, or converting from overhead to underground service? CAS Electric handles underground electrical across Franklin County and the Greater St. Louis area — Pacific, Washington, Union, Sullivan, St. Clair, Eureka, Wildwood, Villa Ridge, and Marthasville — proper burial depths, correct conductor sizing, permits, and utility coordination.

    About Underground Electrical Services

    Underground electrical looks simple from above ground but there's a lot going on: correct burial depth per NEC 300.5 (depends on voltage, whether it's in conduit, whether it's under concrete, and what type of cable), proper direct-burial or conduit-rated conductors, sweep bends at every direction change, warning tape above the conductor, and correct terminations at both ends. Getting it wrong means a failed inspection or a service call to dig it up in a few years.

    Common underground projects for our Franklin County customers: feeder from the main house panel to a detached garage or shop (typically 60–100A sub-panel service), service lateral from Ameren's transformer to a new build or replacement service, buried run to a pool equipment pad or hot tub, low-voltage or line-voltage landscape lighting circuits, and buried feeds to outbuildings, barns, or well pumps.

    We handle 811 utility locates, trenching or directional boring coordination, conductor pulling, terminations at both ends, and the permit/inspection. On longer runs we use trenchers or hire a boring contractor; on shorter runs we can hand-trench or use a mini-excavator.

    Why Choose Underground from CAS Electric

    Correct NEC 300.5 burial depths — passes inspection
    Direct-burial or conduit-rated conductors sized for the load and distance
    811 utility locates coordinated before any digging
    Trenching or directional boring options
    Correct terminations at both ends and warning tape above
    Permit and inspection handled

    Our Process

    Underground services are quoted per project based on run length, conductor size, and trenching method. We provide a free written estimate after a site visit.

    1. 1

      Site walk & scope

      We walk the run, identify obstacles, and design conductor size accounting for voltage drop over the distance.

    2. 2

      811 locates & permit

      We call 811 for utility locates and pull the electrical permit before any digging.

    3. 3

      Trench, pull, terminate

      Trench to correct depth, install conduit or direct-burial cable, pull conductors, terminate at both ends with correct labeling.

    4. 4

      Backfill, inspect, energize

      Trench inspected before backfill in most jurisdictions, then closed up, terminations energized, and system tested.

    Why Choose CAS Electric

    • Correct NEC 300.5 burial depths — first-time inspection pass
    • Voltage-drop calculations for long runs — no undersized conductors
    • 811 locates and permits handled
    • Trenching, hand-digging, or directional boring based on the site
    • Clean restoration of trench area

    Frequently Asked Questions

    How deep does buried electrical need to be?+

    NEC 300.5 depths vary: 24 inches for direct-burial residential branch circuits, 18 inches for PVC conduit, 6 inches for GFCI-protected low-voltage lighting circuits. Under a concrete driveway or slab, 18 inches with 4 inches of concrete cover works. We follow the correct depth for your situation.

    Do you handle 811 utility locates?+

    Yes — we call 811 before any digging. Ameren, Spire, water, and communications utilities mark their lines within 2–3 business days at no cost. We work around what they mark.

    Can you power a detached garage or shop?+

    Yes — one of our most common underground jobs. Typical scope is a 60–100A sub-panel in the garage/shop fed from the main house panel via a buried feeder. Includes a disconnect at the outbuilding and separate grounding electrode system per NEC 250.32.

    Overhead to underground service conversion?+

    Yes — many homeowners convert overhead services to underground when upgrading a panel or replacing an aging service mast. Requires Ameren approval and a service lateral trench from the transformer, but it's a clean way to remove the overhead drop from the house.

    Can you trench or do we need a separate contractor?+

    We handle trenching for shorter runs directly. For longer runs or difficult ground (rock, tree roots), we coordinate with a trenching or directional-boring subcontractor.

    Get a Free Underground Estimate

    Licensed, insured, owner-operated. We respond to all estimates within 1 business day.